EPSRC logo

Details of Grant 

EPSRC Reference: EP/T029080/1
Title: A new multi-scale x-ray micro computed tomography machine to enable (image-guided) non-destructive inspections of decellularised tissue
Principal Investigator: Hagen, Dr CK
Other Investigators:
Researcher Co-Investigators:
Project Partners:
Henry Royce Institute Nikon PerkinElmer, Inc. (International)
Department: Medical Physics and Biomedical Eng
Organisation: UCL
Scheme: New Investigator Award
Starts: 01 April 2021 Ends: 31 December 2023 Value (£): 232,000
EPSRC Research Topic Classifications:
Medical Imaging
EPSRC Industrial Sector Classifications:
Healthcare
Related Grants:
Panel History:
Panel DatePanel NameOutcome
05 May 2020 Healthcare Technologies Investigator Led Panel May 2020 Announced
Summary on Grant Application Form
Tissue engineering - aimed at developing "lab-grown" organs and tissue by combining appropriate scaffolds and cells - could solve one of the biggest medical problems of our times, the shortage of donor organs. While the pool of scaffold materials is large (e.g. natural/synthetic biomaterials), there is consensus that the extracellular matrix (ECM) of the target tissue is an excellent choice as it possesses native structural and biomechanical properties. ECMs can be derived from cadaver tissue (e.g. from animals) through a process called decellularization, by which the tissue undergoes several cycles of flushing with detergents and enzymes. A successfully decellularised tissue is characterised by the absence of cellular material and the presence of an intact ECM. Imaging, for assessing the ECM, is an extremely important tool for the development of decellularisation methods that are simultaneously gentle and effective.

This project is about developing a new imaging tool for characterising decellularised tissue based on x-ray micro computed tomography (CT). Since micro-CT is a non-destructive technique, the inspected samples can be used further in longitudinal studies or be implanted into animals to test their performance in vivo. In comparison, the current gold standard techniques for inspecting ECMs (histology, electron microscopy) require that samples are sliced, sectioned and/or stained in preparation for being imaged, prohibiting using them in any further studies.

A number of substantial developments will be needed before micro-CT can become a valuable tool for validating decellularisation techniques and other methodologies in tissue engineering. Currently, micro-CT fails to meet the complex imaging needs of this field, which often requires multi-scale and multi-contrast approaches. First, a micro-CT machine with zooming in capabilities would be required to inspect the multi-level structure of ECMs. Second, decellularised tissue generally exhibits weak x-ray attenuation; hence, the micro-CT machine should provide access to phase contrast alongside attenuation contrast, which is known to provide a much better visualisation of tissue scaffolds than the latter.

The micro-CT machine proposed here will have both these functionalities. It will exploit an innovative imaging mechanism that is underpinned by the idea to structure the x-ray beam into an array of narrow (micrometric) beamlets via a mask placed immediately upstream of the sample. This provides flexibility in terms of spatial resolution, as this metric - unlike in conventional micro-CT scanners - is not defined by the blur of the source and detector. Instead, resolution is driven by the beamlet width, which can be made smaller than the intrinsic system blur, bearing unique potential for fast resolution switching and multi-scale imaging. Second, it provides access to complementary contrast channels (phase, ultra-small angle x-ray scattering). These channels result from small x-ray photon deviations which occur alongside attenuation when x-rays interact with matter. While most conventional micro-CT scanners are blind to these effects, the machine proposed here will enable their detection, allowing to reconstruct three sets of complementary tomographic images for each sample. While the phase channel can provide a much higher contrast-to-noise ratio than the attenuation channel, the ultra-small angle x-ray scattering channel encodes the presence of sub-resolution features in a sample. The latter bears unique potential for image-guided zooming in.

The project will culminate in the design, construction and test of an experimental prototype for image-guided multi-scale and multi-contrast imaging with a field of view of up to 10 cm by 10 cm, which may be expanded to larger dimensions in the future. A broad range of decellularised tissues will be scanned, and the results benchmarked against the current gold standard (histology or electron microscopy).

Key Findings
This information can now be found on Gateway to Research (GtR) http://gtr.rcuk.ac.uk
Potential use in non-academic contexts
This information can now be found on Gateway to Research (GtR) http://gtr.rcuk.ac.uk
Impacts
Description This information can now be found on Gateway to Research (GtR) http://gtr.rcuk.ac.uk
Summary
Date Materialised
Sectors submitted by the Researcher
This information can now be found on Gateway to Research (GtR) http://gtr.rcuk.ac.uk
Project URL:  
Further Information:  
Organisation Website: